Performance

Energy

Thermal insulation - Uf
1.3 W/m²K
Thermal insulation - Uw
0.89 W/m²K
Uw Dependencies
Frame-vent: Ug 0.6W/m²K, warm edge spacer,@1.23x1.48m (104mm sight line), 36mm glass

Comfort

Air tightness
0.01 cfm/ft³
Water tightness
20 psf
Air tightness
Class 4 (600Pa)
Water tightness
Class E900 (900Pa)
Wind load resistance
Class C5 (2000Pa)
AMAA rating
Class AW
PG rating
70
Acoustics STC
50 dB
Acoustics OITC
44 dB
Acoustics - Rw(C;Ctr)
TuTi: 46(-1;-3) dB DC: 44(-2;-4) dB
Opening & closing resistance
Class 3

Safety

Burglar resistance
RC2 - RC3 - PAS 24
Impact resistance
I5 - E5
Operating Forces Class
Class 1
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2800 mm
Min. width of vent
450 mm
Max. width of vent
1700 mm
Max. weight of vent
200 kg
Max. weight of glass
1200 kg

Sightlines

Min. frame width (inward opening)
53 mm
Min. vent width (inward opening)
37 mm
Min. frame-vent width (inward opening)
97 mm
Min. vent-vent width (inward opening)
142 mm
Min. frame width (outward opening)
20 mm
Min. vent width (outward opening)
96 mm
Min. frame-vent width (outward opening)
116 mm
Min. vent-vent width (outward opening)
243 mm
Min. width T-profile
80 mm
Depth frame
77 mm
Depth Vent
87 mm
Depth frame-vent
87 mm

Glazing

Rebate height
27 mm
Glazing method
Dry glazing - Siliconized glazing - Internal glazing - External glazing - Glazing bead - Structural Glued Glazing
Min. glass thickness - frame/element
4 mm
Max. glass thickness - frame/element
58 mm
Min. glass thickness - vent
13 mm
Max. glass thickness - vent
68 mm