Skip to main content

ConceptWall 60 Structural Clamped

Technical information

Performance

Energy

Thermal insulation - Uw Double
0.23 Btu/hr.ft².°F
Thermal insulation - Uw Triple
0.14 Btu/hr.ft².°F

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
RE1200 (1200 Pa)
Wind load resistance
Class A5 (2000Pa)
Acoustics STC
39 dB
Acoustics - Rw(C;Ctr)
47(-2;-6) dB

Safety

Impact resistance
I5 - E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Max. height of vent
2000 mm
Min. width of vent
450 mm
Max. width of vent
2500 mm
Max. weight of vent
180 kg
Min. intertia mullion - Ix
44.6 cm4
Max. intertia transom - Ix
632 cm4
Min. intertia transom - Iy (glass load)
32.8 cm4
Max. intertia transom - Iy (glass load)
89 cm4

Sightlines

Min. width T-profile
60 mm
Min. visible width (interior view)
60 mm
Min. visible width (exterior view)
20 mm
Min. depth mullion
62.5 mm
Max. depth mullion
251.5 mm
Min. depth transom
67.2 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing - External glazing - Structural Glued Glazing - Structural clamped glazing - Structural Glued Stepped Glazing
Min. glass thickness - frame/element
27 mm
Max. glass thickness - frame/element
63 mm