Skip to main content

ConceptWall 60 Mullion Transom

Technical information

Performance

Energy

Thermal insulation - Uf
0.8 W/m²K

Comfort

Air tightness
Class 4 (600Pa)
Water tightness
RE1200 (1200 Pa)
Wind load resistance
E2400 (2400Pa)
Acoustics - Rw(C;Ctr)
47(-2;-5) dB

Safety

Burglar resistance
RC2 - RC3
Impact resistance
I5 - E5
* Note: Performances and properties may be different depending on the profile combinations

Properties

Max. dimensions & weight

Min. height of vent
600 mm
Min. width of vent
450 mm
Max. weight of vent
180 kg

Sightlines

Min. width T-profile
60 mm
Min. visible width (interior view)
60 mm
Min. visible width (exterior view)
60 mm

Glazing

Rebate height
25 mm
Glazing method
Dry glazing - External glazing - Pressure plate glazing - Structural Glued Glazing - Structural clamped glazing
Min. glass thickness - frame/element
22 mm
Max. glass thickness - frame/element
62 mm