MasterLine 8
Technical informationPerformance
Energy
- Thermal insulation - Uw Double
- 0.26 Btu/hr.ft².°F
- Thermal insulation - Uw Triple
- 0.2 Btu/hr.ft².°F
- Thermal insulation - Uf
- 1.3 W/m²K
- Uw Dependencies
- Single inward opening door: Ug 0.6W/m²K, warm edge spacer, @1.23x2.18m, 36mm glass
- Thermal insulation - Ud
- 0.98 W/m²K
Comfort
- Air tightness
- 0.01 cfm/ft³
- Water tightness
- 15 psf
- Air tightness
- Class 4 (600Pa)
- Water tightness
- Class 7A (300Pa)
- Wind load resistance
- Class C3 (1200Pa)
- AMAA rating
- Class AW
- PG rating
- 70
- Acoustics STC
- 43 dB
- Acoustics OITC
- 35 dB
- Acoustics - Rw(C;Ctr)
- 43(-1;-4) dB
- Opening & closing resistance
- Class 8
Safety
- Burglar resistance
- RC2 - RC3 - PAS 24
- Impact resistance
- I5 - E5
- Fire resistance
- EI₂ 30
Properties
Max. dimensions & weight
- Min. height of vent
- 500 mm
- Max. height of vent
- 3000 mm
- Min. width of vent
- 500 mm
- Max. width of vent
- 1400 mm
- Max. weight of vent
- 250 kg
- Max. weight of fixed part
- 250 kg
- Max. weight of glass
- 1200 kg
Sightlines
- Min. frame width (inward opening)
- 68.5 mm
- Min. vent width (inward opening)
- 78.5 mm
- Min. frame-vent width (inward opening)
- 153 mm
- Min. frame width (outward opening)
- 42.5 mm
- Min. vent width (outward opening)
- 104.5 mm
- Min. frame-vent width (outward opening)
- 153 mm
- Min. width T-profile
- 50 mm
- Min. height treshold
- 0 mm
- Depth frame
- 77 mm
- Depth Vent
- 77 mm
- Depth frame-vent
- 77 mm
Glazing
- Rebate height
- 27 mm
- Glazing method
- Dry glazing - Siliconized glazing - Internal glazing - Glazing bead
- Min. glass thickness - frame/element
- 4 mm
- Max. glass thickness - frame/element
- 58 mm
- Min. glass thickness - vent
- 4 mm
- Max. glass thickness - vent
- 58 mm